Hotel engineering lamp customization based on standard have?

by:Rongde     2021-01-16
Often hotels of different functional areas, light intensity distribution of light distribution curve, light intensity in the center and half should have required parameters, such as light intensity. In general the lobby of the hotel the height is very high. For above the height 6 meters, beam Angle is too large will cause the ground light intensity is insufficient. For the guest room space such as if the beam Angle is too narrow, can cause the ground too bright, the problem of insufficient vertical illumination. If more than 6 m, and high for a narrow beam of LED lighting lamps and lanterns, providing continuous, uniform brightness. Such as distance is 6 m, it light distribution curve at the center of the light intensity, 1 m above the ground should be not less than 500 CD; If no more than 6 m high jump, can consider to use ribbon or planar illuminator. Hotel engineering process steps and process are the custom of lamps and lanterns with conventional lamps and lanterns is the same, but the requirement of engineering lamps and lanterns made more strict than normal, because of his size is larger, if not making good technology, its defect is easy to expose, points to the lamps and lanterns, the custom hotel engineering lamps and lanterns, in accordance with the standards of what? 1. Size the size of the lamps and lanterns of custom-made according to customer's request, but we as a manufacturer of custom need to pay attention to is on the premise of making rational layout, see if any out of the floor bear weight, operators do not conform to the requirements of the design, rather than the tianma sky, phase out some unrealistic beyond the lamps and lanterns of zero point, very prone to accidents. 2. Wire due to the lamps and lanterns are connected 220 v high voltage power supply, so use accessories to overall consideration of wire wire cross-sectional area, the size of the high power of electricity, so want to use 2 - 4 square wire, to ensure that the voltage stability. Don't cause strange trip, it has a great influence on the hotel's reputation is. 3. Wire connection is tight, after the joint must use insulation pacifier fixed, using good quality electrical tape for sealing, ensure the long term in the electricity in the process of wire connection won't because temperature is too high, cause wire falls off, cause an accident. 4. Hotel engineering lamps and lanterns is in the process of making the framework of passivation of must do, not too sharp edges and corners, must carry on the passivation treatment, so as to reduce adverse factors to low, will not leave a safety hazard to the follow-up work. 5. Engineering lamps and lanterns of custom during the installation, the installation personnel to do a good job in the reinforcement of lamps and lanterns with general custom size and weight of lamps and lanterns is relatively larger, do each parts are firmly fixed in the position, can not have any chances. We all his life, to do the common things good we, with the same spirit of craftsmen opened new journey - - - - - - - - - - Lighting more lighting design can directly to lamp act the role ofing exhibition site to choose, welcome the arrival of a friend
Custom message
Contact